SCX03 installed on the minus terminal of the battery Loose connections may cause sparks, heating, and even a fire. It is recommended that the shunt is installed in the negative line if possible.ĬAUTION: After connecting the shunt, make sure that all the connections between cables and shunt are tight. The configuration process is described in PICO’s manual. Connect all consumers and charging sources to the OUT terminal on the shunt.Įach correctly connected shunt needs to be configured.Connect batteries/batteries bank minus or plus terminal through the shunts IN terminal.Connect the temperature sensor to the shunt and place it near the battery/battery bank (optional).Connect shunt voltage sensing input to a battery terminal.Connect the shunt to Simarine’s PICO via the SICOM port.Disconnect the battery/battery bank plus and minus terminal, for safety reasons.Connectingįor the proper function of Simarine’s SC3O3/SC5O3 digital shunt it is necessary to take the following steps: Continuous current Area 500A 220mm2 400 A 150mm2 300 A 95mm2 200 A 50mm2 100 A 25mm2ĬAUTION: Failure to observe the required cable cross-section can damage the shunt, wiring, or cause a fire. Minimum power cable cross-section requirement at a maximal temperature of insulation 70 ☌ (160 ☏). CABLES Cable lengthĢx2x0.25 mm2 Twisted pair (recommended) Power cable If not possible, use the following table to determine the right cable type. Cablesįor the SiCOM connection use the supplied cable. Place back the shunt cover and screw the four screws on the cover of the shunt unit.You can fix the shunt with the supplied screws using two holes on the bottom of the casing. To install the shunt use the supplied voltage cables find a place no further than 3 m away from the battery/battery bank. Remove the shunt cover by unscrewing four screws on top of the shunt cover.Should the acid come in contact with eyes, skin, or clothing, wash it immediately with soap under fresh water for at least 15 minutes, and seek medical support immediately.Į – 2x Voltage & 2x Resistance input InstalationĬAUTION: install the shunt module in a clean dry place, protected from accidental spilling of liquids. When working with batteries, you should wear protective clothing and eye protection.ĬAUTION: Batteries contain acid, a corrosive, colorless liquid that will burn your eyes, skin, and clothing. SafetyĮlectrical specialists with proper safety equipment should make installation of Simarine electronics. SC505 is capable of measuring continuous current up to 500 A and is suitable for maximal power of 6000 W at 12 V or 12000 W at 24 V. SC503 is a high precision combo shunt for PICO battery monitor with 2x voltage, 2x temperature, 1x socket for a temperature sensor with JST connector, and 1x current sensor up to 500A for up to 75V systems. SC303 is capable of measuring continuous current up to 300 A and is suitable for maximal power of 3600 W at 12 V or 7200 W at 24 V The innovative combination of shunt and tank level module. Additionally, it allows monitoring tanks for fuel, fresh and greywater. It can be used for monitoring the current draw of heavy consumers (inverters, bow, and stern thrusters, anchor winches) and current generators (shore power chargers and solar panels). SC303 is an active combo shunt for PICO battery monitor with 2x voltages, 2x tank level or temperature, 1x socket for a temperature sensor with JST connector, and 1x current sensor up to 300A for up to 75V systems. The innovative combination of shunt and tank level module.Simarine’s high precision SCX03 (SC303 & SC503) active digital shunt measures voltage, current, and temperature of the battery or battery bank. 8.1 Related Manuals / Resources Introduction
0 Comments
Leave a Reply. |
Details
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |